UCEL provides man lift elevator systems designed to support maintenance access and industrial operations requiring safe vertical transportation. These systems are commonly used for controlled access applications where personnel and tools require dependable movement across multiple levels.
Industrial man lifts are generally designed for maintenance and lower-traffic environments, commonly supporting capacities below 1,400 lbs, depending on system configuration and project requirements.
UCEL supplies both standard and customized vertical access systems designed to support project-specific operational requirements and site conditions.
A manlift elevator is a vertical transportation system designed to move personnel and tools safely between levels within industrial environments. These systems are frequently used in manufacturing facilities, warehouses, industrial processing plants, and maintenance applications where dependable access is required.
UCEL is committed to supporting a wide range of vertical access requirements with engineered systems designed for demanding environments. Our industrial man lifts use rack-and-pinion technology to provide consistent operation and long-term performance.
System features may include:
Each man lift elevator system is configured according to operational requirements and project specifications.
Industrial environments often require dependable access systems that support personnel movement while maintaining operational efficiency.
Man lift elevator systems can be used across:
Industrial man lifts support maintenance personnel and equipment transportation in environments where safe access between levels is required.
UCEL has a long history of supplying industrial vertical transportation equipment and working with established manufacturers. This approach allows us to provide access systems designed for dependable operation and long-term performance.
Every manlift elevator solution is selected with a focus on:
From compact installations to larger industrial environments, systems can be configured to align with project requirements.
Our rugged manlifts and maintenance access systems use reliable rack-and-pinion designs. Car and tower components are manufactured using high-tensile steel designed for long-term operation and durability.
Available material and system options include:
Systems can be adapted to accommodate specialized operating environments and application requirements.
Facilities operating aging access systems may require a manlift replacement elevator to improve operational performance and support changing site demands.
Replacement considerations may include:
UCEL can assist in identifying replacement configurations suited to existing facilities and future operational requirements.
Depending on application requirements, systems may include:
These features help support productivity while maintaining dependable site access.
Selecting the appropriate man lift elevator depends on operating conditions, environmental factors, load requirements, and application needs.
UCEL works with industrial facilities and project environments requiring dependable vertical access systems designed for long-term operation.
Contact our sales team for a consultation on upcoming projects.
UCEL MANLIFT PRODUCT TABLE
| UCEL MANLIFTS | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| MODEL | HS400F | HS450F | HS600F | HS1200F | HS1500F | HS2000F | HS2800F | HS3200F | CUSTOM* | |
| CAPACITY | LBS | 880 | 1000 | 1320 | 2645 | 3300 | 4400 | 6200 | 7000 | 16,000 |
| KG | 400 | 450 | 600 | 1200 | 1500 | 2000 | 2800 | 3200 | 7240 | |
| SPEED* | FPM | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 300 |
| M/MIN | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | ||
| DIMENSIONS* | FEET | 3’x3’10” | 4’x4’4″ | 3’5″x4’10” | 4’5″x7’3″ | 5’x7’3″ | 5’x8’10” | 5’x12’4″ | 5’x13’6″ | 8′ x 24′ |
| METRE | 0.9×1.2 | 0.9×1.3 | 1.0×1.5 | 1.3×2.2 | 1.5×2.2 | 1.5×2.7 | 1.5×3.7 | 1.5×4.1 | 2.4 x 7.3 | |
| MOTORS | HP | 2×5.3 | 2×5.3 | 2×7.4 | 2×10 | 2×10 | 2×12.3 | 3×12.3 | 3×15 | 4×30 |
| KW | 2×4 | 2×5.5 | 2×5.5 | 2×5.5 | 2×7.5 | 2×9.2 | 3×11 | 3×11 | 4×22 | |
| VFD | HP | 20 | 24 | 30 | 40 | 50 | 60 | 60 | 75 | 215 |
| KW | 15 | 18 | 22 | 30 | 37 | 45 | 45 | 55 | 160 | |
| FULL LOAD | AMPS | 30 | 40 | 50 | 60 | 70 | 80 | 80 | 90 | 180 |
| STARTING | AMPS | 40 | 50 | 60 | 70 | 80 | 90 | 90 | 100 | 225 |
This table represents our popular manlift elevator models and does not necessarily reflect all we offer. Please contact for more details. *Counterweights may change electrical requirements or capacity. *VFD is Variable Frequency Drive.
A man lift elevator is used to transport personnel and tools safely between levels in industrial facilities and maintenance environments.
Industrial man lifts are commonly used in:
Many maintenance-oriented systems commonly operate below 1,400 lbs, depending on configuration and project requirements.
Yes. Systems can include customized controls, communication systems, monitoring capabilities, and environmental protection options.
A manlift replacement elevator is a modernized access system designed to replace aging equipment that no longer meets operational or site requirements.
Yes. Specialized configurations may include protective materials and NEMA-rated components designed for challenging industrial environments.